QUESTIONS? CONTACT US: 952-881-3727

Store Categories

APC AP7841 200/208V 30A (20)C13 (4)C19 Zero U Metered Rack PDU Surge Protector

Click on Thumbnails to Enlarge

APC AP7841 200/208V 30A (20)C13 (4)C19 Zero U Metered Rack PDU Surge Protector

APC AP7841 200/208V 30A (20)C13 (4)C19 Zero U Metered Rack PDU Surge Protector

Availability: Out of stock

$109.90

Product Details

APC AP7841 200/208V 30A (20)C13 & (4)C19 Outlet Zero U Metered Rack PDU Surge Protector

APC P/N: AP7841

Condition: Tested pull - Guaranteed 100% Working. Some PDUs have sticker residue or velcro straps attached to them. We have updated these with latest firmware available from APC and reset them to factory default.

Default login: apc

Default password: apc

PDUs have mounting pegs/buttons attached to them. No other accessories included. Console cable is not included.

Input Voltage: 200V , 208V , 230V

Input Frequency: 50/60 Hz

Maximum Input Current: 30A

Regulatory Derated Input Current: 24A

Input Connector(s): NEMA L6-30P

Cord Length: 10 ft

Output Voltage: 200V , 208V , 230V , 240V

Load Capacity (VA): 4992 VA

Output Connector(s): (20) IEC 320 C13 & (4) IEC 320 C19

30-Day Warranty!

Manufacturer's description:

AP7841Features

Rack PDU, Metered, Zero U, 30A, 200/208V, (20)C13 & (4)C19

  • Resettable circuit breakers
    Enables a quick recovery from overload events.
  • Toolless Rack Mounting Capabilities
    Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.
  • Vertical Mounting Capabilities
    Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

Metered Rack PDUFeatures & Benefits

Marketing Features
  • Local and web-based monitoring
    Status available to customers both in the data center and remotely
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Agility
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Availability
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.